【Voltage Compatibility】
When using electrical appliances, please note that they are designed for Japanese voltage specifications (90-110V), so if you use them with a different voltage, it may cause a malfunction.
【Plug Type】
Our products use Japanese plug types (A or B type).
Please use a conversion adapter if necessary.
【Important Note on Transformers and Adapters】
A transformer adjusts voltage to match your device’s requirements.
A conversion adapter only changes the plug shape and does not adjust voltage.
Using only a conversion adapter without a transformer may result in damage to the product.
【Liability】
We are not responsible for malfunctions or damages caused by improper use, such as operating the product without a transformer.
------------------------------------------------------------------------------------------------------------------
DC voltage = 600.0mV/6.000/60.00/600.0/600V (input impedance: 10MΩ, 600mV only 100MΩ), ±0.5%rdg±2dgt(600.0mV/6.000/60.00/600.0V), ±0.8%rdg±3dgt(600V )
AC voltage = 6.000/60.00/600.0/600V (input impedance: 10MΩ), ±1.5%rdg±5dgt(6.000V), ±1.2%rdg±3dgt(60.00/600.0V), ±1.5%rdg±5dgt(600V)
AC/DC current = 600.0/6000μA/60.00/600.0mA/6.000/10.00A, ±1.2%rdg±3dgt(600.0/6000μA/60.00/600.0mA), ±2.0%rdg±5dgt(6.000/10.00A)
Its multi-function: resistance, continuity, diode test, capacitance, frequency, DUTY